COMMERCIAL · INDUSTRIAL · INSTITUTIONAL · CIVIL
Dynamic Cone Penetrometer (DCP) Soil Testing
Weak soil layers, soft zones and poorly compacted fill are not visible from the surface, yet they can lead to settlement beneath slabs, foundations and roadways. PURLIFT® performs its own Dynamic Cone Penetrometer (DCP) soil testing to measure the soil’s resistance to penetration and identify potentially weak layers at each test location.
Before construction or slab repairs, the results help guide further investigation and the appropriate work, based on measured site conditions rather than on assumptions.
Since 2012 · 7,000+ customers · RBQ licensed · Québec & Southeastern Ontario
THE VALUE OF WORKING TOGETHER
Our Approach
✓
Decisions Based on Measured Data
Each DCP test produces a resistance profile at the test location and helps identify changes between soil layers. Your team can locate weak layers and soft zones before choosing a repair or construction approach.
✓
Minimally Invasive Testing
No excavation and no heavy equipment. In existing buildings, PURLIFT® tests through small holes drilled in the slab. Access holes are patched and the area is left clean.
✓
Testing Where Drill Rigs Can’t Go
DCP testing is ideal for warehouses, plants and institutional buildings where a drill rig can’t go. Work is planned to limit disruption to ongoing activities.
✓
From Diagnosis to Solution
Where suitable for the site, the same PURLIFT® team can carry out Deep Soil Injection (DSI) using structural polyurethane resin and, if needed, lift and re-level the slab. Test findings flow directly into the repair strategy.
THE RIGHT STARTING POINT
When DCP Testing Makes Sense
Whether you are preparing a new build, investigating settlement in an existing building or verifying completed work, DCP testing provides targeted measurements where they are needed. PURLIFT® works with engineering firms, contractors, property managers and infrastructure owners to place test points where they answer the project’s questions.
1
Verifying subgrade, fill and compaction before pouring slabs or footings.
2
Locating soft zones between geotechnical boreholes.
3
Slabs or foundations showing settlement or cracking, before designing a stabilization or slab lifting repair.
4
Warranty claims, disputes, due diligence and verifying results after remediation.
A PROJECT IN CONTEXT
Case Study: Municipal road in Racine
No geotechnical study was available for a road culvert affected by recurring seasonal settlement. Preliminary DCP testing confirmed heterogeneous, moderate-quality backfill, with penetration refusal around 0.6 m deep, consistent with voided zones causing differential settlement. The results guided a Deep Soil Injection (DSI) treatment, and post-injection DCP testing verified increased soil bearing capacity and compaction.
≈0.6 m
refusal depth in preliminary testing
Before and AFter
DCP testing at both stages
1 day
on site for the treatment
FROM OBSERVATION TO SCOPE
How DCP Testing Works
01
Site Review
PURLIFT® reviews plans, visible distress and any existing geotechnical data, then proposes the number and location of test points.
02
Testing
On open sites, testing is performed from grade. In existing buildings, PURLIFT® works through small holes drilled in the slab. Testing time depends on site access, soil conditions and the number of test locations.
03
Findings & Recommendations
Access holes are patched and the area is left clean. PURLIFT® provides its findings and recommendations according to the schedule agreed for your project, including whether further investigation, Deep Soil Injection (DSI) or slab lifting should be considered.

METHOD & SITE CONDITIONS
What DCP Testing Measures
DCP testing measures how far a steel cone penetrates the soil under a series of hammer blows. The measurements provide a resistance profile at each test location and help identify changes between soil layers. Depending on the test method and site conditions, suitable correlations can help estimate certain soil properties. Results are interpreted alongside other available information; further investigation may be needed to confirm voids or determine a foundation’s allowable bearing capacity.
Related services
QUESTIONS BEFORE THE WORK
Know Your Ground Before You Decide
Every site presents different conditions. PURLIFT® confirms test locations, access and scheduling with your team before testing begins.
LET’S REVIEW YOUR PROJECT
Differential Settlement issues
Tell us about your project and PURLIFT® will recommend a testing plan. Include your company, role, project location, asset type and timeline, along with the reason for testing: pre-construction verification, settlement or cracking, a warranty or due diligence review, or verification after remediation. Available plans, borehole logs or geotechnical reports help us place test points where they matter.
No budget or documentation is required to get started. Simply have any available plans, drawings or reports on hand for our initial discussion.